================================================================================ PAGE 41 ================================================================================ Example ofanEvent 2.TheactionsforStartby,Onstart,andOnstopare: a)Startby:Contact3closed->InputContact (3,true) ================================================================================ PAGE 42 ================================================================================ b)Onstart:RoutevideoIn3toVideoout2->CrossSwitch (3,2,0) c) Onstop:Clearvideooutput2->ClearVideoOutput (2) 3.AfterthesetuphasbeensenttotheGeViServer, theeventcanbetestedwiththe GeViAPITestClient 4.Ifyouleftclickinputcontact3theeventisstarted.Youwillseethatvideoinputstream 3isroutedtovideooutput2.After5secondstheoutputisclearedagain.Youcanalso seetheeventbeingstartedinthecommunication log. 5.Theeventcanberetriggered. Ifyouleftclickinput3againwhiletheeventisrunning, the5secondautostoptimestartsoveragain. 6.YoucanalsostarttheeventbysendingaStartEvent message(StartEvent (ID, "MessageName") ). ================================================================================ PAGE 43 ================================================================================ Alarms(optional) Duetothelargeamountofvideocamerasconnected tomodernvideosurveillance systems, operatorscannotobserveallthestreamsatthesametime.Moreover, onlycertainincidents areofinterestorneedaction.Therefore, itishelpfulthatapreselection ofthevideomaterial showntotheuseriscarriedoutbythesystem.Oftenspecialactionshavetobetakenifapar- ticularsituationishappening. Asanexampleassumethataparkinglotwithabarrieratthe entranceisbeingmonitored. Theoperatorissupposed toopenthebarrieraftermakingsure thatawaitingvehicleisallowedtoenter.Normally, theoperatorwouldhavetowatchthe streamofthecamerapermanently andactonit.IncaseslikethisGeutebrück systemscan assistbyprovidingalarms.Alarmsareverysimilartoevents,butoffermoreversatileoptions forcustomizing anddefiningrequireduserinteraction. AlarmOptions GeViSetoffersseveraloptionsforalarms. Option Description Name Alarmname–canbeusedinactions Description Fieldforthedescription ofanalarm AlarmID Alarmidentifier --canbeusedinactions Active Alarmscanonlybetriggered ifmarked Active Priority Alarmscanhaveapriority from1(high)to10(low).Ahigherpriority alarmwilldisplace alowerpriority oneifconfigured tobeshownon thesamemonitor group Monitor Group Several monitors thatareaddressed asagroupforeasieradmin- istration Cameras Listofcameras thatarerelevant forthealarm.Theirpictures are shownonthemonitor groupincaseanalarmoccurs Retriggerable Ifchecked, thealarmcanberetriggered byitsinitialactivator. Popup(Retrigger) ================================================================================ PAGE 44 ================================================================================ Option Description Undoacknowledge (Retrigger)Ifset,thealarmhasalready beenacknowledged andthealarmis retriggered, thestatewillberesettonotacknowledged. Userspecific (Retrigger) Ifchecked, acustom listofactions canbeaddedwhichwillbe executed onaretrigger eventofthealarm StartbyAction Listofactions. Anyoftheactions willstartthealarm(logical OR) OnstartAction Listofactions. Alloftheactions willbesentonstart(logical AND) Acknowledge byAction Listofactions. Anyoftheactions willacknowledge thealarm(logical OR) Onacknowledge Action Listofactions. Alloftheactions willbesentonacknowledge (logical AND) QuitbyAction Listofactions. Anyoftheactions willquitthealarm(logical OR) OnquitAction Listofactions. Alloftheactions willbesentonquit(logical AND) Configuring anAlarm Configure analarmfortheparkinglotscenarioasdescribed above.Assumethatthedetec- tionofavehicleisdonebyasensorondigitalinput1(vehicleisdetectedonclose).After checkingifthevehiclemayentertheoperatormustopenthebarrier.Todosoheacknowl- edgesthealarmbypushingabuttonconnected todigitalinput2.Asthebarrieriscontrolled bydigitaloutput1theOnacknowledge actionmustopenthiscontact.Afterthevehiclehas passed,theoperatormustquitthealarmbypushingabuttonconnected todigitalinput3.On quitthebarriermustbeclosedbyclosingdigitaloutput1.Theparkinglotissurveilledbytwo camerasoninputs4and7.Duringthealarm,thesemustberoutedtooutputs1and2. 1.AlarmsaredisplayedinMonitorGroups.FirstdefineoneInGeViSet. a)Server->Monitorgroups->Add b)Setthegroup’sNameandDescription toMonitorGroup1 c)Addvideooutputs1and2tothegroup ================================================================================ PAGE 45 ================================================================================ d) Leavetherestofthesettingsastheyare 2.AddanewalarminGeViSet: Server->Alarms->Add a)IntheGeneraltab,setNameandDescription toParkingLot b)PresstheMonitorgroupbuttonandaddMonitorGroup1 c)AddVideoinput4andVideoinput7toCameras ================================================================================ PAGE 46 ================================================================================ AlarmSettings 1 ================================================================================ PAGE 47 ================================================================================ d)IntheActionstab,settheStartbyactiontoInputContact ,theGlobalContactID to 1andChangedTo totrue.AddtheCaptionvehicledetected e)SettheAcknowledge byactiontoInputContact ,theGlobalContactID to2and ChangedTo totrue.AddtheCaptionbuttonacknowledged pressed f) SettheOnacknowledge actiontoOpenContact ,andtheGlobalContactID to1. AddtheCaptionopeningbarrier g)SettheQuitbyactiontoInputContact ,theGlobalContactID to3andChangedTo totrue.AddtheCaptionbuttonquitpressed h)SettheOnquitactiontoCloseContact ,andtheGlobalContactID to1.Addthe Captionclosingbarrier ================================================================================ PAGE 48 ================================================================================ AlarmSettings 2 ================================================================================ PAGE 49 ================================================================================ 3.Sendthesetuptotheserver 4.TestthenewalarminGeViAPITestClient a)Clearvideooutputs1and2byright-clickingonthem. b)Simulatethearrivalofthevehiclebyleft-clickinginput1. c)Checkifthealarmistriggeredbyverifyingthatstreams4and7aredisplayedon monitors1and2.Notethattheoutputs’colorchangedtoredwhichindicatesan alarmfeed.YoushouldalsofindtheAlarmStarted ()actionintheCommunication log d)Acknowledge thealarmandopenthebarrierbyleft-clickinginputcontact2.Make surethatthisleadstotheopeningofoutput1andanAlarmAcked ()actionappearing inthelog. e)Quitthealarmbyleft-clickinginputcontact3.Thevideooutputs’colorshould changetogreenasthealarmhasfinished.Thebarrier(output1)shouldhaveclosed. ================================================================================ PAGE 50 ================================================================================ Switching Video Thoughmonitorgroupsdatebacktoanaloguevideorecording, theideabehindthemcomesin handywhencomplexsituations aretobepresented tooperators. InmodernCCTVsystems mostofthesourcesaredigitalonesandtheviewersrunassoftwareondedicated consoles. Nevertheless theconceptofmonitorgroupscanstillbereproduced withGeutebrück’s sys- tems.Thestandardviewer--GscView--canberemotecontrolled toshowpredefined scene setupsinawaysimilartomonitorgroups. InthischapteryouwilllearnhowtoswitchbetweentwouserdefinedGscViewscenesbytrig- geringaGeViSoftalarm.Youwillhaveanormal4-by-4scenedisplaying 16channelsoflive footagefromaGeViScope. OntriggeringanalarminGeViSoft, GscViewwillbeswitchedtoa 2-by-2scenedisplaying predetermined videochannels. Scenario Assumethefollowingsituation,whichiscloselyrelatedtoConfiguring anAlarminchapter Alarms: Configure analarmfortheparkinglotscenario.Assumethatthedetectionofavehicleisdone byasensorondigitalinput1(vehicleisdetectedonclose).Aftercheckingifthevehiclemay enter,theoperatormustopenthebarrier.Thishappensonacknowledging thealarmbypush- ingabuttonconnected todigitalinput2.Asthebarrieriscontrolled bydigitaloutput1,theOn acknowledge actionmustopenthiscontact.Afterthevehiclehaspassed,theoperatormust quitthealarmbypushingabuttonconnected todigitalinput3.Onquitthebarrierhavetobe closedbyclosingdigitaloutput1.Theparkinglotissurveilledbytwocamerasoninputs4and 7.Duringthealarm,thesemustberoutedtooutputs1and2ofa2-by-2sceneMyScenein GscView. Beforeandafterthealarm,all16GeViScope channelsshouldbedisplayedina4- by-4sceneMyStartScene inGscView.